Samenvatting:

Serosurveillance and seroprevalence studies are an essential tool to monitor vaccine-preventable diseases. We have developed a magnetic bead-based pentaplex immunoassay (MIA) for the simultaneous detection of IgG antibodies against diphtheria toxin (DT), tetanus toxin (TT), pertussis toxin (PT), filamentous hemagglutinin (FHA) and pertactin (Prn). The in-house pentaplex MIA showed a good correlation with commercial ELISAs with correlation coefficients between 0.89 for PT and 0.98 for TT. Intra- and inter-assay variability was <10%. A total of 670 anonymized serum samples collected in 201…
Lees meer

Samenvatting

Serosurveillance and seroprevalence studies are an essential tool to monitor vaccine-preventable diseases. We have developed a magnetic bead-based pentaplex immunoassay (MIA) for the simultaneous detection of IgG antibodies against diphtheria toxin (DT), tetanus toxin (TT), pertussis toxin (PT), filamentous hemagglutinin (FHA) and pertactin (Prn). The in-house pentaplex MIA showed a good correlation with commercial ELISAs with correlation coefficients between 0.89 for PT and 0.98 for TT. Intra- and inter-assay variability was <10%. A total of 670 anonymized serum samples collected in 2012 in Belgian adults (ages 20-29.9 years) were analyzed. Geometric mean concentrations (GMC) were 0.2 (0.13-0.29) IU/mL for DT, 0.63 (0.45-0.82) IU/mL for TT, 3.9 (2.6-5.8) IU/mL for PT, 16.3 (11.7-22.7) IU/mL for FHA and 15.4 (10.1-23.6) IU/mL for Prn. Antibody concentrations were below the protective level of 0.1 IU/mL in 26.4% of the sera for DT and in 8.6% of the sera for TT. Anti-PT IgG concentrations indicative of recent pertussis infection (>125 IU/mL) were detected in 1.2% of the subjects. High anti-PT antibodies were not correlated with high antibodies against any of the four other vaccine antigens. This pentaplex MIA will be used for a new large-scale Belgian serosurveillance/seroprevalence study of diphtheria, tetanus and pertussis.

Associated health topics:

Tetanus [12]
Difterie [13]

Source URL:https://sciensano.be/nl/biblio/a-belgian-serosurveillance-seroprevalence-study-diphtheria-tetanus-and-pertussis-using-a-luminex

Links
[1] https://sciensano.be/sites/default/files/vaccines-04-00016.pdf [2] http://dx.doi.org/10.3390/vaccines4020016 [3] https://sciensano.be/nl/user/4839/biblio [4] https://sciensano.be/nl/biblio?f%5Bauthor%5D=33081&amp;f%5Bsearch%5D=Pi%C3%A9rard%2C%20Denis [5] https://sciensano.be/nl/biblio?f%5Bauthor%5D=33714&amp;f%5Bsearch%5D=Huygen%2C%20Kris [6] https://sciensano.be/nl/biblio?f%5Bkeyword%5D=1431&amp;f%5Bsearch%5D=Belgian [7] https://sciensano.be/nl/biblio?f%5Bkeyword%5D=17769&amp;f%5Bsearch%5D=Diphtheria [8] https://sciensano.be/nl/biblio?f%5Bkeyword%5D=17556&amp;f%5Bsearch%5D=Luminex [9] https://sciensano.be/nl/biblio?f%5Bkeyword%5D=2013&amp;f%5Bsearch%5D=pertussis [10] https://sciensano.be/nl/biblio?f%5Bkeyword%5D=1191&amp;f%5Bsearch%5D=study [11] https://sciensano.be/nl/biblio?f%5Bkeyword%5D=17775&amp;f%5Bsearch%5D=Tetanus [12] https://sciensano.be/nl/gezondheidsonderwerpen/tetanus [13] https://sciensano.be/nl/gezondheidsonderwerpen/difterie