Résultats de la recherche - 28 results

The performance of a point-of-care test for the diagnosis of Neurocysticercosis in a resource-poor community setting in Zambia- a diagnostic accuracy study.

at any stage was limited for all tests (TS POC, rT24H- EITB and antigen ELISA). With further development the TS POC CC may enable a better detection and faster referral of NCC patients who may benefit ...

Personalized bacteriophage therapy outcomes for 100 consecutive cases: a multicentre, multinational, retrospective observational study.

our analysis is limited by the uncontrolled nature of these data, it indicates that BT can be effective in combination with antibiotics and can inform the design of future controlled clinical trials. ...

Pyrogen testing of phage therapeutic products

is pivotal to limit the risk of non-endotoxin contamination. These pyrogens can be detected by the monocyte activation test (MAT), which employs human blood cells to quantify pyrogenicity in vitro. In ...

The analysis of cannabinoids in e-cigarette liquids using LC-HRAM-MS and LC-UV.

using the ‘total error’ approach, applying accuracy profiles and conforming to ISO17025. None of the analysed samples exceeded the legal limit for the total amount of ∆9- THC present. However, of the 20 ...

The analysis of cannabinoids in e-cigarette liquids using LC-HRAM-MS and LC-UV

applying accuracy profiles and conforming to ISO17025. None of the analysed samples exceeded the legal limit for the total amount of ∆9- THC present. However, of the 20 CBD-liquids investigated in this ...

The GEONs API-fingerprint program: Tackling falsifications of APIs

API testing within the network is limited, compared to the surveillance of finished products. To tackle the issue of falsified API detection the API-working group (API- WG) of the GEON organizes ...

CBD oils on the Belgian market: A validated MRM GC-MS/MS method for routine quality control using QuEChERS sample clean up

(0.05–0.1–0.2% (w/v)) for CBN. The detection limits for CBT, CBD, CBC, Δ8- THC, CBN and for the other cannabinoids of interest, were 10 and 14 ng/mL respectively. The accuracy profile values for CBD and CBN showed ...

Use of Whole Genome Sequencing Data for a First in Silico Specificity Evaluation of the RT-qPCR Assays Used for SARS-CoV-2 Detection.

started in December 2019. COVID-19 cases are confirmed by the detection of SARS-CoV-2 RNA in biological samples by RT-qPCR. However, limited numbers of SARS-CoV-2 genomes were available when the first ...

Characterization and hazard identification of substandard and falsified antimicrobials encountered in Belgium

about 35% of the samples contained known and/or unknown impurities beyond the Ph. Eur. limits [3]. Concerning the dissolution tests, 47% of samples were not compliant as the amount of drug released is ...

A new approach to define acceptance limits for hematology in external quality assessment schemes.

Laboratory Medicine (EQALM) decided to perform a statistical study with the aim of establishing appropriate acceptance limits (AL) allowing harmonization between the evaluation procedures of European EQAS ...

QR code

QR code for this page URL